INDIGO Home University of Illinois at Urbana-Champaign logo uic building uic pavilion uic student center

Analysis of Respiratory Program Practices and Simulated Workplace Protection Factor Studies

Show full item record

Bookmark or cite this item: http://hdl.handle.net/10027/19570

Files in this item

File Description Format
PDF Sietsema_Margaret.pdf (2MB) (no description provided) PDF
Title: Analysis of Respiratory Program Practices and Simulated Workplace Protection Factor Studies
Author(s): Sietsema, Margaret
Advisor(s): Brosseau, Lisa M.
Contributor(s): Conroy, Lorraine M.; Jones, Rachael; Bodurtha, Paul; Peters, Thomas
Department / Program: School of Public Health
Graduate Major: Public Health Sciences-Environmental and Occupational Health Sciences
Degree Granting Institution: University of Illinois at Chicago
Degree: PhD, Doctor of Philosophy
Genre: Doctoral
Subject(s): Respiratory Protection Real-time SWPF N95
Abstract: Background: Respiratory protection is an important way to protection people while they work. A good respiratory protection program utilizes a strong written program and also applies appropriate fit-testing measures to ensure a respirator fits and adequately protects employees while they work. Little is known regarding how well this fit test reflects how the respirator performs while someone performs their workplace tasks and if there are specific activities that would cause the respirator to fail. Methods: This research looks at the effectiveness of acute care hospital respiratory protection programs and compares them to practices as interpreted from interview responses. Next this research validates real-time methodology for measuring respirator fit on N95 filtering facepiece respirators. This real-time methodology is then used in an ensemble study of first responders and a study of realistic healthcare activities. Results: Results from the analysis of hospital written respiratory protection programs showed very few hospital designated a program administrator or performed a proper risk assessment. Written programs lacked sufficient detail in all aspects. There was no correlation between written programs and hospital practices. Real-time methodology was successfully validated against a gold standard fit-testing methodology. The real-time ensemble research with first responders showed how big of an effect the ensemble can have on respirator fit and also the importance of repeated measures to detect trends in respirator fit over time. The realistic healthcare activity research again showed the importance of repeated measures of fit and a low within-subject variability in respirator fit and a high between-subject variability. Conclusions: This research was the first of its kind to analyze how well-written hospital respiratory protection programs are. This research begins to answer questions regarding how well a respirator fits while employees perform their actual jobs and how tests can be conducted to measure real-time respirator fit.
Issue Date: 2015-07-21
Genre: thesis
URI: http://hdl.handle.net/10027/19570
Rights Information: Copyright 2015 Margaret Sietsema
Date Available in INDIGO: 2017-07-22
Date Deposited: 2015-05
 

This item appears in the following Collection(s)

Show full item record

Statistics

Country Code Views
United States of America 196
China 60
Ukraine 19
Russian Federation 17
Iran 10

Browse

My Account

Information

Access Key